Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 101: Mild steel – 3" under water 200 amps, Plasma / air shield

4-36
MAX200
Instruction Manual
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
1/4
1/8
3
125
145
3700
0.5
3/8
1/8
3
130
80
2000
1.0
1/2
1/8
3
130
70
1800
2.0
5/8
.16
4
135
60
1500
2.0
3/4
3/16
5
140
48
1200
2.5
7/8
1/4
6
140
38
950
3.0
1
1/4
6
145
25
680
3.0
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
6
3
1/8
125
3700
145
0.5
8
3
1/8
125
2800
110
0.5
10
3
1/8
130
2000
80
1.0
12
3
1/8
130
1800
70
2.0
15
4
.16
135
1500
60
2.0
20
5
3/16
140
1200
48
2.5
25
6
1/4
145
680
25
3.0
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
72
48-52
64-68
280
70
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
34
3.33-3.6 4.4-4.7
132
4.8
Mild Steel – 3" Under Water
200 amps
•
O
2
Plasma / Air Shield
This gas combination gives superior cut speed, minimum dross, minimum amount of surface nitriting and
excellent weldability.
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
020424
Shield
020605
Nozzle
020423
Retaining cap
220021
Electrode
020604
Swirl ring