Operation, Metric, English – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 79: Mild steel – above water 200 amps, Plasma / air shield

4-14
MAX200
Instruction Manual
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
1/4
1/8
3
120
160
4060
0.5
3/8
1/8
3
125
100
2540
1.0
1/2
.16
4
125
80
2030
2.0
5/8
.16
4
130
70
1780
2.0
3/4
3/16
5
135
55
1400
2.5
7/8
1/4
6
135
45
1140
2.5
1
1/4
6
140
35
890
2.5
1-1/4
1/4
6
150
22
560
*
1-1/2
1/4
6
155
15
380
*
1-3/4
5/16
8
165
10
250
*
2
5/16
8
170
7
180
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
6
3
1/8
120
4060
160
0.5
8
3
1/8
125
3000
120
0.5
10
3
1/8
125
2540
100
1.0
12
4
.16
125
2030
80
2.0
15
4
.16
130
1780
70
2.0
20
5
3/16
135
1400
55
2.5
25
6
1/4
140
890
35
2.5
32
6
1/4
150
560
22
*
50
8
5/16
170
180
7
*
4.0
60
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
72
48-52
64-68
270
34
3.3-3.6
4.4-4.7
127
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Torch-to-Work
Distance
Travel Speed
Travel Speed
Mild Steel – Above Water
200 amps
•
O
2
Plasma / Air Shield
This gas combination gives superior cut speed, minimum dross, minimum amount of surface nitriting and
excellent weldability.
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
+ SilverPlus provides increased life to high duty cycle users in most applications. The hafnium wears to approximately two times
the depth of a standard electrode (220021). Arc voltage may need to be increased by 5-10 volts throughout the electrode life
to maintain proper cut height parameters.
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
Production cutting above 1 inch (25 mm) not recommended.
020424
Shield
020605
Nozzle
120837
Retaining cap
220021 (standard) Electrode
220083 (optional)
SilverPlus electrode+
020604
Swirl ring