Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 111: Mild steel – beveling consumables 200 amps, Plasma / air shield

4-46
MAX200
Instruction Manual
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
1/4
1/8
3
120
160
4060
0.5
3/8
1/8
3
125
100
2540
1.0
1/2
.16
4
125
80
2030
2.0
5/8
.16
4
130
70
1780
2.0
3/4
3/16
5
135
55
1400
2.5
7/8
1/4
6
135
45
1140
2.5
1
1/4
6
140
35
890
2.5
1-1/4
1/4
6
150
22
560
*
1-1/2
1/4
6
155
15
380
*
1-3/4
5/16
8
165
10
250
*
2
5/16
8
170
7
180
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
6
3
1/8
120
4060
160
0.5
8
3
1/8
125
3000
120
0.5
10
3
1/8
125
2540
100
1.0
12
4
.16
125
2030
80
2.0
15
4
.16
130
1780
70
2.0
20
5
3/16
135
1400
55
2.5
25
6
1/4
140
890
35
2.5
32
6
1/4
150
560
22
*
50
8
5/16
170
180
7
*
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
72
48-52
64-68
270
60
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
34
3.3-3.6
4.4-4.7
127
4.0
Mild Steel – Beveling Consumables
200 amps
•
O
2
Plasma / Air Shield
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 1 inch (25 mm) not recommended.
120257
Water Tube
120833
Swirl ring
120258
Electrode
120259
Nozzle
020423
Retaining cap
120260
Shield