Setup – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 53

MAX200
Instruction Manual
3-25
14
SETUP
FUNCTION
COLOR
1X4
5X1
PLASMA START-SIG
BLU
1
2
PLASMA START-COM
BLK
5
4
SHIELD
N/A
10
—
INITIAL HEIGHT-SIG
YEL
2
1
INITIAL HEIGHT-COM
BLK
6
3
SHIELD
N/A
11
—
AUTO HEIGHT-SIG
BRN
3
6
AUTO HEIGHT-COM
BLK
7
5
SHIELD
N/A
12
—
SERIAL INPUT DATA-SIG
GRN
4
9
SERIAL INPUT DATA-COM
BLK
8
10
SHIELD
N/A
13
—
SERIAL OUTPUT DATA-SIG
RED
9
7
SERIAL OUTPUT DATA-COM
BLK
15
8
SHIELD
N/A
14
—
RED
—
UNUSED
WHT
19
—
N/A
—
RED
—
UNUSED
GRN
20
—
N/A
—
24 VAC AUX-HOT
ORN
29
11
24 VAC AUX-NEUT
BLK
23
12
SHIELD
N/A
24
—
120 VAC-NEUT
WHT
35
16
120 VAC-HOT
BLK
36
15
SHIELD
N/A
31
—
KEY (BLANK)
—
22
—
Power Supply
SR Remote
Figure 3-12
MAX200 to Switch Remote Interface Cable Diagram
Part No.
Length
023319
25 ft. (7.6 m)
023328
50 ft. (15.2 m)
023329
75 ft. (23 m)
023330
100 ft. (30.5 m)
023331
150 ft. (46 m)
023332
200 ft. (61 m)