Operation, Metric, English – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 82: Stainless steel – above water 200 amps, Air plasma / air shield

MAX200
Instruction Manual
4-17
14
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
3/16
1/8
3
125
220
5600
0.0
1/4
1/8
3
130
195
5000
0.5
3/8
1/8
3
130
145
3700
1.0
1/2
1/8
3
135
105
2700
2.0
5/8
.16
4
140
75
1900
2.0
3/4
3/16
5
140
55
1400
2.5
7/8
1/4
6
145
40
1000
3.0
1
1/4
6
150
30
760
*
1-1/4
1/4
6
160
15
380
*
1-1/2
1/4
6
170
10
250
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
5
3
1/8
125
5600
220
0.0
6
3
1/8
130
5000
195
0.5
10
3
1/8
130
3700
145
1.0
12
3
.16
135
2700
105
2.0
15
4
.16
140
1900
75
2.0
20
5
3/16
140
1400
55
2.5
25
6
1/4
150
760
30
*
32
6
1/4
160
380
15
*
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
66
44-48
58-62
270
60
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
31
3.0-3.3
4.0-4.3
127
4.0
Stainless Steel – Above Water
200 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 7/8 inch (21 mm) not recommended.
020424
Shield
020608
Nozzle
120837
Retaining cap
220021
Electrode
020607
Swirl ring