Page 107: Aluminum – 3" under water 200 amps, Air plasma / air shield

4-42
MAX200
Instruction Manual
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
3/16
1/8
3
135
210
5300
0.5
1/4
1/8
3
140
170
4300
1.0
3/8
1/8
3
145
125
3150
2.0
1/2
1/8
3
150
90
2240
2.5
5/8
.16
4
155
65
1650
3.0
3/4
3/16
5
160
45
1150
3.0
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
5
3
1/8
135
5300
210
0.5
6
3
1/8
140
4300
170
1.0
10
3
1/8
145
3150
125
2.0
12
3
1/8
150
2240
90
2.5
15
4
.16
155
1650
65
3.0
20
5
3/16
160
1150
45
3.0
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
66
44-48
58-62
280
70
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
31
3.0-3.3
4.0-4.3
132
4.8
Aluminum – 3" Under Water
200 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
020424
Shield
020608
Nozzle
020423
Retaining cap
220021
Electrode
020607