Page 78: Air plasma / air shield

MAX200
Instruction Manual
4-13
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
.050 (18GA.)
3/32
2.5
110
320
8100
0.0
1/16
3/32
2.5
110
300
7600
0.0
.075
3/32
2.5
110
220
5600
0.0
1/8
3/32
2.5
110
140
3550
0.5
.158
3/32
2.5
115
120
3050
*
.197
3/32
2.5
115
50
1250
*
1/4
3/32
2.5
120
35
850
*
3/8
3/32
2.5
125
20
500
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
2
2.5
3/32
110
5600
220
0.0
3
2.5
3/32
110
3550
140
0.5
4
2.5
3/32
115
3050
120
*
5
2.5
3/32
115
1250
50
*
6
2.5
3/32
120
850
35
*
10
2.5
3/32
125
500
20
*
Travel Speed
Travel Speed
Torch-to-Work
Distance
Torch-to-Work
Distance
Shield
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Plasma
Gas
Flowrate
(SCFH)
English
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
4.0
25
16-20
56-60
275
60
12
1.1-1.4
3.9-4.1
129
Mild Steel – Above Water
40 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speeds, low dross levels and is very economical. Some surface
nitriting can occur.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 1/8 inch (3 mm) not recommended.
020514
Shield
020689
Nozzle
020423
Retaining cap
120547
Electrode
020613
Swirl ring