Setup, Power supply end 1x3 ihs end, Part no. length – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 59

MAX200
Instruction Manual
3-35
14
SETUP
LEGEND – POWER SUPPLY END – 1X3
LEGEND – IHS END
PIN COLOR
FUNCTION
SOCKET
COLOR
FUNCTION
1
Red
IHS Complete Sig.
1
Red
IHS Complete Sig
2
Grn
Upper Limit Sw. Sig.
2
Grn
Upper Limit Sw. Sig
3
3
Blk
Upper Limit Sw. Com
4
Blk
IHS Complete Com
4
Blk
IHS Complete Com
5
Blk
Upper Limit Sw Com
5
Drain
Shield – Grn/Blk
6
6
7
Drain
Shield – Wht/Blk
7
Key
8
Drain
Shield – Red/Blk
8
Wht
AC Power
9
Drain
Shield – Grn/Blk
9
Blk
AC Power
10
11
Blk
AC Power
12
13
14
Wht
AC Power
Part No.
Length
023111
25 ft (7.6 m)
023112
50 ft (15 m)
023155
75 ft (23 m)
023113
100 ft (30.5 m)
023114
150 ft (46 m)
023284
200 ft (61 m)
Figure 3-16
MAX200 to IHS Interface Cable
Indicates Pairs.
NOTE:
On IHS End, Cut Red/Black Shield
& White/Black Shield Wires
008176 Pin (9)
008190 Key
047002 Cable, 22–3 Pr Shielded
Belden #8777
Insert Key In Face Of Plug
Tapered End First Until
It “Locks” In Detent
008186
Socket (7)
008187 Strain Relief
008192 Strain Relief
008202 Plug, Shell 17–14
008185 Plug, Shell 13–9
Power Supply End
1X3
IHS End