Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 84: Stainless steel – above water 40 amps, Air plasma / air shield

MAX200
Instruction Manual
4-19
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
.050 (18GA.)
3/32
2.5
120
145
3700
0.0
1/16
3/32
2.5
120
120
3050
0.0
1/8
3/32
2.5
125
75
1900
0.5
1/4
1/8
3
135
30
750
*
3/8
1/8
3
140
12
300
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
3
2.5
3/32
125
1900
75
0.5
6
3
1/8
135
750
30
*
10
3
1/8
140
300
12
*
Torch-to-Work
Distance
Travel Speed
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
4.0
25
16-20
56-60
275
60
12
1.1-1.4
3.9-4.1
129
Stainless Steel – Above Water
40 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.
020514
Shield
020689
Nozzle
020423
Retaining cap
220021
Electrode
020613
Swirl ring