Operation, English, Metric – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 91: Aluminum – above water 40 amps, Air plasma / air shield

4-26
MAX200
Instruction Manual
15
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
3/32
3/32
2.5
120
140
3550
0.0
1/8
3/32
2.5
130
100
2550
0.5
1/4
1/8
3
140
35
900
*
3/8
1/8
3
150
15
350
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
3
2.5
3/32
130
2550
100
0.5
6
3
1/8
140
900
35
*
10
3
1/8
150
350
15
*
Torch-to-Work
Distance
Travel Speed
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
12
1.1-1.4
3.9-4.1
129
4.0
60
25
16-20
56-60
275
Aluminum – Above Water
40 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 1/8 inch (3 mm) not recommended.
020514
Shield
020689
Nozzle
020423
Retaining cap
220021
Electrode
020613
Swirl ring