Operation, Metric, English – Hypertherm MAX200 Machine Torch Plasma Arc Cutting System User Manual
Page 83: Stainless steel – above water 100 amps, Air plasma / air shield

4-18
MAX200
Instruction Manual
14
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
1/8
3/32
2.5
125
140
3560
0.0
3/16
1/8
3
130
110
2800
0.5
1/4
1/8
3
130
80
2030
0.5
3/8
1/8
3
135
55
1400
0.5
1/2
1/8
3
140
35
890
*
5/8
.16
4
145
25
635
*
3/4
3/16
5
150
20
510
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
3
2.5
3/32
125
3560
140
0.0
5
3
1/8
130
2800
110
0.5
6
3
1/8
130
2030
80
0.5
10
3
1/8
135
1400
55
0.5
12
3
1/8
140
890
35
*
15
4
.16
145
635
25
*
20
5
3/16
150
510
20
*
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
37
22-26
54-58
270
60
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
17
1.5-1.8
3.7-4.0
127
4.0
Stainless Steel – Above Water
100 amps
•
Air Plasma / Air Shield
This gas combination gives good cut speed, low dross levels and is very economical. Some surface
nitriting and surface oxidation of alloying elements can occur.
Set plasma gas inlet pressure to 90 psi (6.2 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 3/8 inch (10 mm) not recommended.
020448
Shield
020611
Nozzle
120837
Retaining cap
120547
Electrode
020607
Swirl ring