Page 86: Stainless steel – above water 200 amps, Plasma / co, Shield

MAX200
Instruction Manual
4-21
14
OPERATION
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(psi)
Run
(psi)
(psi)
(Inches)
(Inches)
(mm)
(Volts)
(ipm)
(mm/min)
(sec)
3/16
1/8
3
125
190
4800
0.5
1/4
1/8
3
130
170
4300
1.0
3/8
1/8
3
130
125
3200
1.5
1/2
1/8
3
135
95
2400
2.0
5/8
.16
4
140
70
1800
2.0
3/4
3/16
5
140
50
1250
2.5
7/8
1/4
6
145
40
1000
3.0
1
1/4
6
150
30
760
*
1-1/4
1/4
6
160
15
380
*
1-1/2
1/4
6
170
10
250
*
Shield
Gas
Pressure
Material
Thickness
Arc
Voltage
Setting
Approx.
Motion
Delay Time
Test
(bar)
Run
(bar)
(bar)
(mm)
(mm)
(Inches)
(Volts)
(mm/min)
(ipm)
(sec)
5
3
1/8
125
4800
190
0.5
6
3
1/8
130
4300
170
1.0
10
3
1/8
130
3200
125
1.5
12
3
.16
135
2400
95
2.0
15
4
.16
140
1800
70
2.0
20
5
3/16
140
1250
50
2.5
25
6
1/4
150
760
30
*
32
6
1/4
160
380
15
*
English
Plasma
Gas
Flowrate
(SCFH)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(SCFH)
Torch-to-Work
Distance
Travel Speed
60
36-40
52-56
210
60
Metric
Plasma
Gas
Flowrate
(l/min)
Plasma Gas
Pressure
Shield
Gas
Flowrate
(l/min)
Torch-to-Work
Distance
Travel Speed
28
2.5-2.8
3.6-3.9
99
4.0
Stainless Steel – Above Water
200 amps
•
N
2
Plasma / CO
2
Shield
This gas combination is used when surface nitriting and surface oxidation of alloying elements is less
important. Electrode life is extended when using this gas combination.
Set plasma gas inlet pressure to 120 psi (8.3 bar)
Set shield gas inlet pressure to 90 psi (6.2 bar)
If leads are greater than 50 feet, increase TEST pressure 5 psi for every extra 50 feet of torch lead length.
* Production cutting above 7/8 inch (21 mm) not recommended.
020424
Shield
020608
Nozzle
120837
Retaining cap
020415
Electrode
020607
Swirl ring