Examples of output circuits, Examples of output circuits -36 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 76

InstallatIon
3-36
HPR800XD Auto Gas –
806500
Examples of output circuits
1. Logic interface, active-high
2. Logic interface, active-low
3. Relay interface
4. Do not use this configuration. Warranty will be void.
High-impedance (≤10 mA)
10K
(optional)
CNC/PLC
5 VDC-24 VDC
C
HPR
E
+
-
HPR
C
E
+
-
5 VDC-24 VDC
High-impedance (≤10 mA)
CNC/PLC
10K
(optional)
CNC/PLC
CNC +24 V
+24 VDC
CNC +24 V
HPR
C
E
+
-
Power
ground
High-current
contact closure
inputs (AC or DC)
°t
Any voltage
voIDS
wARRAN
ty
HPR
Install a
Jumper
108056
J304
C
E
+
-
External relay
24VDC low-power coil
≤10 mA or ≥2400 ohms
All relay coils require a freewheeling diode
across the relay coil
This manual is related to the following products: