Command table (5 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 344
Appendix B – CnC interfACe protoCol
b-10
HPR800XD Auto Gas –
806500
command table (5 of 14)
ID
command
System
Description
079 GET_PS_INFO
Manual gas system
Auto gas system
Returns pressures, system state, and system error,
space-delimited
Data:
None
Return value:
Plasma cutflow pressure (0044 = 44 psi)
Plasma preflow pressure (0044 = 44 psi)
Shield cutflow pressure (0044 = 44 psi)
Shield preflow pressure (0044 = 44 psi)
Current setpoint (amps)
System state (see table V) (0003 = state 3)
System error (see table IV) (0000 = error 0)
Cut gas 1 pressure (0044 = 44 psi)
Cut gas 2 pressure (0044 = 44 psi)
N
2
Mix inlet pressure (0044 = 44 psi)
Gas2 Mix inlet pressure (0044 = 44 psi)
Note: Cut gas 1, Cut gas 2, N
2
mix inlet, and Gas 2 mix inlet are
not measured in the manual gas console configuration.
Sample:
>079A0<
>079PC0044 PP0042 SC0034 SP0035 CS0040 ST0003
ER0000 CG0000 CG0000 MV0000 MV0000DE<
084 DOWNLOAD_SOFTWARE
Not currently implemented on the
HD4070 or the HPR systems
TBD
Download new firmware to the plasma system.
Data:
TBD
Return value:
1 = packet accepted, 0 = not accepted
Sample:
TBD
085 WAKE
Manual gas system
Auto gas system
This command is used to wake a system and enable its
transmitter to communicate on a multi drop line.
Data:
System ID, which is set by dipswitches on PC board.
Return value:
Echo of the command
Sample:
>0850CD<
>0850CD<
086 SLEEP
Manual gas system
Auto gas system
Tell all systems on the line to disconnect their transmitters
Data:
None
Return value:
None
Sample:
>0869E<
No response