Command table (13 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 352
Appendix B – CnC interfACe protoCol
b-18
HPR800XD Auto Gas –
806500
ID
command
System
Description
126 GET_INFO2
Auto gas control
board only
See 079
127 GET_INFO3
Auto gas control
board only
See 079
131 CLEAR WARNINGS
Manual gas system
Auto gas system
This command will clear error codes less than #43.
Sample:
>13195<
>1311C6<
132 READ COOLANT PRESSURE
HPR260 ONLY
This command returns the raw A/D value for coolant pressure.
83 counts = 225 psi
73 counts = 200 psi
Sample:
>13296<
>13280FE<
133 GET CONTROL DATA3
HPR400XD ONLY This command provides data for the 3rd and 4th choppers used in
the HPR400 system.
Chopper C temp (raw A/D)
Chopper D temp (raw A/D)
Chopper C current (amps)
Chopper D current (amps)
Data:
None
Return value:
Above info space-delimited.
Sample:
>13397<
>133CCT0482 CDT0021 CCC0000 CDC000050<
134 READ ERROR LOG
ALL HPR SYSTEMS This command will return the last 4 error codes the system
encountered. The log will only record errors (error code values
greater than 0). It ignores error code 0, which indicates no error
or that an error has been cleared.
The error codes are listed space-delimited, most recent error first.
Data:
None
Return value:
Error – most recent (see table IV Error Codes)
Error #2
Error #3
Error – oldest error
Sample:
>13498<
>134020 020 024 0534A<
command table (13 of 14)