beautypg.com

Pilot arc current levels, Pilot arc current levels -43 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 257

background image

Maintenance

HPR800XD Auto Gas –

806500

5-43

Pilot arc current levels

The pilot arc current level will vary according to the arc current selected, and the process. See table below.

Pilot arc current

Plasma

gas

30

amps

45

amps

50

amps

80

amps

130

amps

200

amps

260

amps

400

amps

600

amps

800

amps

O

2

25

30

30

30

30

40

40

60

60

60

N

2

25

30

30

30

35

40

40

60

60

60

H35

25

30

30

30

35

40

40

60

60

60

F5

25

30

30

30

35

40

40

60

60

60

Air

25

30

30

30

35

40

40

60

60

60

transfer current

Plasma

gas

30

amps

45

amps

50

amps

80

amps

130

amps

200

amps

260

amps

400

amps

600

amps

800

amps

O

2

10

10

10

10

15

20

20

30

30

30

N

2

10

10

10

10

15

20

20

30

30

30

H35

10

10

10

10

15

20

20

30

30

30

F5

10

10

10

10

15

20

20

30

30

30

Air

10

10

10

10

15

20

20

30

30

30