Pilot arc current levels, Pilot arc current levels -43 – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 257
Maintenance
HPR800XD Auto Gas –
806500
5-43
Pilot arc current levels
The pilot arc current level will vary according to the arc current selected, and the process. See table below.
Pilot arc current
Plasma
gas
30
amps
45
amps
50
amps
80
amps
130
amps
200
amps
260
amps
400
amps
600
amps
800
amps
O
2
25
30
30
30
30
40
40
60
60
60
N
2
25
30
30
30
35
40
40
60
60
60
H35
25
30
30
30
35
40
40
60
60
60
F5
25
30
30
30
35
40
40
60
60
60
Air
25
30
30
30
35
40
40
60
60
60
transfer current
Plasma
gas
30
amps
45
amps
50
amps
80
amps
130
amps
200
amps
260
amps
400
amps
600
amps
800
amps
O
2
10
10
10
10
15
20
20
30
30
30
N
2
10
10
10
10
15
20
20
30
30
30
H35
10
10
10
10
15
20
20
30
30
30
F5
10
10
10
10
15
20
20
30
30
30
Air
10
10
10
10
15
20
20
30
30
30