Command table (9 of 14) – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 348
Appendix B – CnC interfACe protoCol
b-14
HPR800XD Auto Gas –
806500
command table (9 of 14)
ID
command
System
Description
102 SET_GAS_IO_FROM_PS
Manual gas system
Auto gas system
This command will allow the user to turn on or off each output
of the processor. After sending this command, the SYSTEM_
RESET command must be issued to restore the processor state.
The I/O are in the following order:
Note: Use caution when selecting gas valves to make
sure fuel and oxidizers are not mixed together
resulting in a combustible mixture.
Data:
1 = On, 0 = Off for each I/O point
Return value:
1 = accepted, 0 = not accepted
Manual gas console
Shield cutflow
(SV16)
Calibrate bypass
(SV13)
Plasma cutflow 1
(SV14)
Ramp-down valve
(SV20)
Shield preflow
(SV17)
Plasma preflow
(SV18)
Plasma cutflow 2
(SV19)
H35 plasma cutflow 2
(SV12)
Spare valve
(SV15)
O
2
shield cutflow
(SV4)
Air shield cutflow
(SV5)
N
2
shield cutflow
(SV6)
Air preflow
(SV7)
N
2
preflow
(SV8)
Air plasma cutflow 2
(SV9)
Air plasma cutflow 1
(SV1)
O
2
plasma cutflow 1
(SV2)
H35 plasma cutflow 1
(SV3)
O
2
plasma cutflow 2
(SV10)
N
2
plasma cutflow
(SV11)
Auto gas console
O
2
inlet
(SV1)
Air
inlet
(SV2)
Air inlet 2
(SV3)
H5
inlet
(SV4)
H35
inlet
(SV5)
F5
inlet
(SV6)
Spare out 1
(Spare)
Ramp-down valve
(SV16)
Non-XD = Spare out 2, XD = Ar inlet2 (SV15)
Gas 2 no mix
(SV14)
Gas 2 mix
(SV13)
N
2
mix
(SV12)
N
2
inlet 2
(SV11)
Air inlet 3
(SV10)
N
2
inlet
(SV9)
O
2
air inlet
(SV8)
Non-XD = CH4 inlet, XD = Ar inlet1 (SV7)
Sample:
>1021111111111111111111167<
>1021C4<