Mild steel, Plasma / o, Shield 30 a – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 149: Metric, English, Marking

OperatiOn
HPR800XD Auto Gas –
806500
4-43
Mild steel
O
2
Plasma / O
2
Shield
30 A
220194
220747
220192
220754
220180
220193
* Pierce complete is recommended for these thicknesses.
Note: Air must be connected to use this process. It is used as the preflow gas.
Select
Gases
Set
Preflow
Set
Cutflow
Material
thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm
Volts
mm
mm/m
mm Factor % Seconds
O
2
O
2
78
17
94
17
0.5
114
1.3
5355
2.3
180
0.1
0.8
115
4225
0.2
1
116
3615
0.3
1.2
117
2865
1.5
119
2210
35
7
2
120
1.5
1490
2.7
0.4
2.5
122
1325
75
3*
123
1160
0.5
4*
125
905
0.7
6*
128
665
1.0
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in
Volts
in
ipm
in
Factor % Seconds
O
2
O
2
78
17
94
17
0.018
114
0.05
215
0.09
180
0.1
0.024
200
0.030
115
170
0.2
0.036
116
155
0.3
0.048
117
110
0.060
119
85
35
7
0.075
120
0.06
60
0.11
0.4
0.105
122
50
75
0.135*
123
40
0.5
3/16*
128
30
0.7
1/4*
25
1.0
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps
mm
in
mm/m
ipm
Volts
N
2
N
2
10
10
10
10
15
2.5
0.10
6350
250
105
Ar
Air
90
10
90
10
9
2.5
0.10
2540
100
80
Marking
Flow rates – lpm/scfh
O
2
Air
Preflow
0 / 0
43 / 90
Cutflow
25 / 52
0 / 0
220340