beautypg.com

Mild steel bevel cutting (standard), Plasma / air shield 260 a, Metric – Hypertherm HPR800XD Auto Gas Rev.2 User Manual

Page 161: English, Marking

background image

OperatiOn

HPR800XD Auto Gas –

806500

4-55

Mild steel bevel cutting (standard)

O

2

Plasma / Air Shield

260 A

220741

220637

220541

220740

220436

220542

220571

Select

Gases

Set

Preflow

Set

Cutflow

Minimum

Clearance

Equivalent

Material

thickness

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

mm

mm

Range (mm) mm/m mm Factor % Seconds

O

2

Air

22

49

76

46

2.0

6

2.8 – 7.6

6500

8.5

300

0.3

8

5470

10

4440

12

3850

0.4

80

49

15

3.6 – 7.6

3130

9.0

250

0.5

20

2170

0.6

22

1930

0.7

84

25

1685

0.8

28

4.8 – 7.6

1445

9.5

200

0.9

32

1135

1.0

38*

895

2.0

44

580

Edge start

50

405

58

290

64

195

Metric

Select

Gases

Set

Preflow

Set

Cutflow

Minimum

Clearance

Equivalent

Material

thickness

Torch-to-Work

Distance

Cutting

Speed

Initial Pierce

Height

Pierce Delay

Time

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

Plasma

gas

Shield

gas

in

in

Range (in)

ipm

in Factor % Seconds

O

2

Air

22

49

76

46

0.08

1/4

0.11 – 0.30

245

0.33

300

0.3

5/16

215

3/8

180

1/2

145

0.4

80

49

5/8

0.14 – 0.30

115

0.35

250

0.5

3/4

90

0.6

7/8

75

0.7

84

1

65

0.8

1-1/8

0.19 – 0.30

55

0.38

200

0.9

1-1/4

45

1.0

1-1/2*

35

2.0

1-3/4

22

Edge start

2

15

2-1/4

12

2-1/2

8

English

Select

Gases

Set

Preflow

Set

Cutflow

Amperage Torch-to-Work

Distance

Marking

Speed

Arc

Voltage

Amps

mm

in

mm/m

ipm

Volts

N

2

N

2

10

10

10

10

18

2.5

0.10

6350

250

135

Ar

Air

30

20

30

20

24

3.0

0.12

2540

100

68

Marking

Flow rates – lpm/scfh

O

2

Air

Preflow

0 / 0

130 / 275

Cutflow

42 / 88 104 / 220

* See the alternate, thick metal piercing, cut chart if you have a problem with excessive slag on the shield or problems with the torch misfiring.