Mild steel underwater cutting, Plasma / air shield 80 a, Metric english – Hypertherm HPR800XD Auto Gas Rev.2 User Manual
Page 153
OperatiOn
HPR800XD Auto Gas –
806500
4-47
Mild steel underwater cutting
No more than 75 mm (3 in) below the surface of the water
O
2
Plasma / Air Shield
80 A
Note: Preflow must be on during IHS.
Flow rates – lpm/scfh
O
2
Air
Preflow
0 / 0
76 / 161
Cutflow
23 / 48
41 / 87
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm
Volts
mm
mm/m
mm Factor %
Seconds
O
2
Air
48
23
78
23
4
116
2.0
3877
4.0
200
0.2
5
118
3407
0.3
6
122
2746
8
125
2162
0.4
10
129
1639
0.5
10
12
132
1271
5.0
250
0.7
15
136
922
0.8
220189
220747
220756
220179
220188
220340
220187
Select
Gases
Set
Preflow
Set
Cutflow
Material
thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
inches
Volts
inches
ipm
inches Factor
%
Seconds
O
2
Air
48
23
78
23
0.135
115
0.10
162
0.150
150
0.2
3/16
117
0.08
140
0.16
200
1/4
123
99
0.3
5/16
125
86
0.4
3/8
128
68
0.5
10
1/2
133
45
0.20
250
0.7
5/8
137
33
0.8