SpecificationS
HPR800XD Auto Gas –
806500
2-5
Power supplies
229 mm
9.00 in
1270 mm
50.00 in
1175 mm
46.25 in
870 mm
34.25 in
851 kg
1877 lb
general
Maximum OCV (U
0
)
360 VDC
Maximum output current (I
2
)
400 Amps
Output voltage (U
2
)
50 – 200 VDC
Duty cycle rating (X)
100% @ 80 kw, 40° C (104° F)
Ambient temperature/Duty cycle
Power supplies will operate between -10° C and +40° C
(+14° and 104° F)
Power factor (cosϕ)
0.98 @ 400 ADC output
Cooling
Forced air (Class F)
Insulation
Class H
Power supply
Ac
voltage
(U
1
)
Phase Frequency
(Hz)
Amperage
(I
1
)
Regulatory
approval
Power kvA
(+/- 10%)
(U
1
x I
1
x 1.73)
Primary Primary
with
Hypernet
Secondary
078578
078586
078594
200/208
3
50/60
262/252
CSA
90.6
078579
078587
078595
220
3
50/60
238
CSA
90.6
078580
078588
078596
240
3
60
219
CSA
90.6
078581
078589
078597
380*
3
50/60
138
CCC
90.6
078582
078590
078598
400
3
50/60
131
CE/GOST-R
90.6
078583
078591
078599
440
3
50/60
120
CSA
90.6
078584
078592
078600
480
3
60
110
CSA
90.6
078585
078593
078601
600
3
60
88
CSA
90.6
* The 380 volt CCC regulatory approval only applies to 50 Hz operation
Note: Each power
supply has
the same
dimensions and
weight
(each power supply has the following specifications)