beautypg.com

Adhesive alert – Harken 7412.13 12V MKIV Electric Jib Reefing & Furling User Manual

Page 6

background image

Preassembly

Rigging Parts Check/Tools/Adhesive

Tools You Will Need

MKIV Furlers are shipped with 3M

®

5200

adhesive. Use adhesives on dry connectors
and foils using the special injection system
described in the assembly section. Parts
may immediately be exposed to rain. Cure
is best at 70 F (22C) with 50% humidity.
Do not apply at temperatures below 40 F
(5C) and above 100F (38C).

Although adhesive has not cured it will
remain in place on foil joints whether
they are left on the ground or raised up
on boat. Foils can be raised immediately
after assembly and sails fitted.

Note: A small amount of adhesive may
bulge out of injection ports. If possible
let system sit for a couple days before
sailing. If adhesive gets on sails remove
using acetone. For faster-curing adhesive,
purchase 4200 Fast Cure.

Note: Damaged foils can be repaired.
Use a hand-held propane torch to heat
joints until foils can be pulled apart.

Adhesive Alert

6

MKIV Unit 2E, 3E

1. Long tape measure

6. Side cutters

11. Center punch

2. Short tape measure

7. Rat-tail file

12. Rigging or black tape

3. Power drill

8. Hex keys (provided)

13. Scissors

4. Drill bit – 5/32" (4mm)

9. Slotted/phillips screwdrivers 14. Metal straight edge

5. Hacksaw

10. Needle-nose pliers

15. Hammer

16. 5 mm Ball-end hex key wrench (recommended but not required)

10

13

12

11

8

7

6

5

3

2

1

15

4

14

9

1. Harken jaw/jaw toggle and link plate assembly required. Sold separately.
2. Mating turnbuckle components, with eye at lower end, must be purchased

separately. See page 8.
3. Headstay may require cutting and shortening to fit Harken toggle. Some

headstays may remain uncut by replacing lower stud of turnbuckle with

stud/eye thus eliminating extra toggle.
4. Rod rigging requires Harken rod adapter stud.

Toggles

WARNING! Wire that is old or damaged may break suddenly,

causing an accident. Headstay condition should be checked

by a professional rigger before reusing.

ROD RIGGING

Harken Rod Adapter

Stud Required

(Sold Separately)

Harken Toggle/

Link Plate Assembly

(Sold Separately)

Unit

Part No.

3E

7413.22 3/4
7413.22 7/8

16

Unit

Part No.

3E

7426 -22

7427 -30

Rod Adapter Stud

Unit

Part No.

2E

7312.22 5/8
7413.22 3/4

Jaw/Jaw Toggle

w/ Link Plate

Unit

Part No.

2E

7424 -12

7425 -17

7426 -22

5. Harken 7406 through-deck fitting for routing power wires through the

deck. Fits

1

/

2

" ID parker hose supplied with unit. Includes three (3) 6 mm x

35 mm fasteners and hose clamp. See page for template.

7406 Aluminum

through-deck fitting

for routing wires

belowdecks