Bevel – Harken 7412.13 12V MKIV Electric Jib Reefing & Furling User Manual
Page 28

28
MKIV Electric Unit 2E, 3E
Commissioning
Electrical System
You must use supplied
1
/
2
" ID Parker
Hydraulic Hose to keep electric motor
compartment water tight.
Slip hose over the wire. Use stainless steel
hose clamp to securely tighten the hose to
the coupling extension tube. If supplied
hose is too short, use a similar
1
/
2
" ID
hydraulic hose.
Secure other end of hose to watertight
through deck fitting so that wires enter
a dry area of the boat.
Clamp host to outside
of motor housing.
Use optional 7406 Power Cable Through-
Deck Fitting for a watertight routing of the
power cable through the deck.
See drilling template on page 45.
Hole saw Ø
1
3
/
8
" (35 mm)
Drill size
1
/
4
" (6.25 mm)
Fasteners (Provided) 6 mm x 35 mm
If required, shorten fasteners or purchase
longer 6 mm stainless steel screws. Use
washers, not provided.
Drill large hole and fastener holes.
Make a slight bevel at the top of the screw
holes to allow sealant to form a small ring.
Use sealant around large deck hole and in
deck screw holes.
Bevel
Deck
Deck
Use 833 blue Loctite
®
in
screw holes in Harken
7406 through-deck fitting.