beautypg.com

2 configuring the network interfaces, 3 configuring the ethernet port – Guralp Systems CMG-CD24S6EAM User Manual

Page 27

background image

CMG-CD24S6EAM

Appendices

8.

After a few seconds, a banner will appear, showing the MAC address of
the network interface, along with software and library version

information. Press the Enter key to access the set-up menu. If you do
not press a key, the system will proceed to boot normally.

4.3.2 Configuring the network interfaces

Once you have access to the networking module's configuration menu, you
can configure it with its proper settings.

During the configuration process, you are prompted, in turn, for every value in
the current section. If you are unsure at any point, pressing the Enter key will

retain the current value. Please note that many values need to be entered
using special codes. These are all documented in the relevant Lantronix

manuals.

From the main menu:

1.

Each channel is configured individually. To configure either press 1
(Channel 1) or 2 (Channel 2).

2.

Set the Baud Rate to 115200. This is the default baud rate for the
CD24's digital output.

3.

The remaining settings can be left at their default values, which is done
by pressing Enter at each prompt until you are returned to the main
menu.

4.

When you have finished setting up the module, apply the new settings
by selecting option 9 Save and Exit. The module will re-boot with the
new settings in effect.

4.3.3 Configuring the Ethernet port

To configure the Ethernet port

1.

If DHCP is not being used to assign IP addresses, enter the required

address manually. The IP address must be set to a unique value in the
network. Enter each octet and press Enter to move to the next octet..

The current value is displayed in parentheses. If you do wish to use
DHCP, enter 0 at each prompt (an IP address of 0.0.0.0 is used to select

DHCP operation).

MAN-C24-0003

24

Issue A - May 2011