beautypg.com

5 warning and error reporting, 1 configurable parameters in simple mode – Guralp Systems CMG-CD24S6EAM User Manual

Page 14

background image

CMG-CD24S6EAM

Setting up the CMG-CD24S6EAM

memory to the GPIO socket, causing it to behave identically to a standard USB
memory stick.

When no power is detected at the GPIO port, the Flash memory is available to
the system as if it were a standard removable mass storage device. All of the

mass storage device recording options described in the CMG-EAM manual
MAN-EAM-0003.

3.5

Warning and error reporting

Each component in the station has a predefined warning and error level. The

status of the components are indicated on the EAM homepage.

Green indicators are shown when the level is above 70%

Amber warnings are displayed when the level falls below 70%

Red errors are displayed when the level falls below 40%

The status of all components can be monitored and if the level falls below a
set percentage a selected output line can be switched from low to high for use

by an external indication system.

To configure the status iolines using the web interface select:

Configuration > All options > Status iolines assertion configuration

To configure the status iolines from the command line, start gconfig and select
“Status iolines assertion configuration” from the top level menu.

3.5.1 Configurable parameters in simple mode

The configurable parameters for recording data in simple mode are shown
below:

Enable: Activates the status iolines assertion server.

MAN-C24-0003

11

Issue A - May 2011