Wiring
Pump Wiring Diagrams
Page 10 MDE-4673 Consumer Electric Pumps Installation / Operation / Parts Manual · May 2007
3) Model 72, 73, and 1820 models: Make field wire connections in the motor junction
box.
Model 1820R models: A separate junction box is supplied with these pump models.
Install the junction box directly below the pump. Make field wire connections in this
junction box using the wiring which extends from factory-installed conduit within the
pump. Do not make connections in the pump motor junction box. Tightly splice wire
connections and secure with a wire nut. Close off the end of the wire nut with
electrical tape.
4) The Aux AC Control Lead is shipped capped from the factory. When used, it connects
to a solenoid valve or fuel management system. Do not connect this wire without first
checking the ON voltage of this line to ascertain compatibility with the equipment
being connected. Voltage is present on this line only after motor reaches full speed.
5) Pulser wiring must be 18AWG and installed in a separate metal conduit away from
all AC wiring except where local regulations dictate otherwise. It cannot share a
common junction box, wiring trough or conduit with any AC wiring.