Installation on an Aboveground Tank - Direct Mount

Installation

Installation on an Aboveground Tank - Direct Mount

1 - Install-a-Socket, screw into 2
2 - Tank Flange, 2” NPT
3- Suction pipe, 1” NPT. Screw into bottom of 1
4 - Emergency Vent
5 - Vented fill cap required
6 - Pressure/Vacuum Vent required
7 - Suction tube must be at a minimum distance

of 100mm from the bottom of the tank.

Installation on an Aboveground Tank - Vacuum Breaker

1 - Vacuum Breaker
2 - Copper Tubing, 1/4”
3 - Alternate Tubing
4 - Bushing 1/8” x 3/4”
5 - Tank Top
6 - Nipple, 2” x 3”
7 - Tee, 2” x 2” x 3/4”
8 - Pump Inlet
9 - NPT Fitting 1/4” x 1/8”
10 - Pump Housing

This manual is related to the following products: