Installation on an aboveground tank - direct mount – Gasboy 70 Series Installation User Manual
Page 11

MDE-4673 Consumer Electric Pumps Installation / Operation / Parts Manual · May 2007
Page 7
Installation on an Aboveground Tank - Direct Mount
Installation
Installation on an Aboveground Tank - Direct Mount
1 - Install-a-Socket, screw into 2
2 - Tank Flange, 2” NPT
3- Suction pipe, 1” NPT. Screw into bottom of 1
4 - Emergency Vent
5 - Vented fill cap required
6 - Pressure/Vacuum Vent required
7 - Suction tube must be at a minimum distance
of 100mm from the bottom of the tank.
Installation on an Aboveground Tank - Vacuum Breaker
1 - Vacuum Breaker
2 - Copper Tubing, 1/4”
3 - Alternate Tubing
4 - Bushing 1/8” x 3/4”
5 - Tank Top
6 - Nipple, 2” x 3”
7 - Tee, 2” x 2” x 3/4”
8 - Pump Inlet
9 - NPT Fitting 1/4” x 1/8”
10 - Pump Housing
This manual is related to the following products: