Installation of the ADDS 4000 Terminal and Okidata Printer

Page 10

MDE-4604 ADDS 4000 Terminal and Okidata® Printer Installation Instructions · February 2007

Okidata 184/186 Setup

To prepare the Okidata printer for operation with the ADDS 4000 terminal and your Gasboy
Fuel Management System, perform the following steps. Install and complete the setup of the
printer as specified in the manufacturer's setup instructions. Then, set up the switches as
follows:

SW1-1 to SW1-8

SW1

SET

Function

SW1-1

ON

Parity: Odd

SW1-2

ON

Parity: Without

SW1-3

ON

Data bits: 8

SW1-4

OFF

Protocol: XON/XOFF (Series 1000 V8.1 or higher, FleetKey V2.1 or
higher, CFN, or TopKAT)

ON

Protocol: Ready/Busy (Series 1000 versions prior to V8.1, FleetKey
versions prior to V2.1, and "A" Systems)

SW1-5

ON

Test select: Circuit

SW1-6

ON

Mode select: Print

SW1-7

ON

Busy line selection: DTR - Pin 20

SW1-8

ON

Busy line selection: DTR - Pin 20

SW2-1 to SW2-3

Baud Rate

SW2-1

SW2-2

SW2-3

9600

OFF

ON

ON

2400

OFF

OFF

ON

1200

ON

ON

OFF

300

ON

OFF

OFF

Note: Any change made to the baud rate must also be changed on the Aux Baud parameter on

the Boundless Terminal Communications setup screen

SW2-4 to SW2-8

SW2

SET

Function

SW2-4

ON

DSR output signal: Active

SW2-5

ON

Buffer threshold: 32 bytes

SW2-6

OFF

Busy signal timing: 1 sec (min.)

SW2-7

ON

DTR signal: Space after power on

SW2-8

OFF

Not used