CFN Series System
2-4
05/28/03
PUMP CONTROL UNIT (PCU)
 
Description 
The pump control unit (PCU) controls most mechanical pumps and some electronic pumps. The 
unit is controlled by a microprocessor and communicates to the site controller via the RS-485 loop. 
 
Each pump control unit can control up to four pumps or remote dispensers. There are two 
different versions of the pump control unit: the retail version (Weights & Measures) and the fleet 
version. Hardware features on the retail version include a battery backup, three solid state relays 
for each pump or remote dispenser (slow flow, fast flow and submersible pump), manual override 
switches, and diagnostic capabilities. The fleet version does not have a battery backup, and has 
only two solid state relays for each pump and remote dispenser. Field wiring connections are 
made to the unit via easy to wire terminal blocks. 
 
The pump control unit can be ordered mounted in a wall-mount box (standard), in the island card 
reader’s post, or as a standalone unit to be located on the island. 
 
Location 
The wall mount version of the pump control unit must be located in an area protected from direct 
contact with weather. Do not install over a hazardous location. The post and standalone version 
of the pump control unit should be located on the fueling island, no closer than 18" from the 
nearest dispenser. The unit is designed for an operating temperature of -40
o
F to 104
o
F with a
relative humidity of 2% to 99% non-condensing. 
 