Modifying nozzle boot – Gasboy M06184K00X User Manual
Page 9
MDE-4487C Atlas™ Dispenser Vapor Recovery Kit (M06184K00X) Installation Instructions · September 2008
Page 9
Installing the M06184K00X Vapor Recovery Kit
3
Install Reel and Support Post Assembly to the side of the dispensing unit and loosely secure
with hardware (items
,
, and
).
Note: The spacer (item
) mounts between the post and side panel. On electronic models, the
spacer mounts to the side panel through a pre-existing plugged hole to the right of the
off-side lever stop. On mechanical models, the spacer mounts to the side panel
replacing the off-side lever stop.
4
Ensuring that the support post is plumb, mark and drill a hole of diameter 5/8 inch and depth
of 1-3/4 inch in the island.
5
Install Bolt Anchor (item
) in the hole. Secure the bottom of the support post with hardware
(items
,
, and
).
6
Tighten all hardware installed in step
.
7
Plug the hole in the bottom of the support post by installing the bottom plug (item
).
Modifying Nozzle Boot
The following parts are required to modify the nozzle boot:
• 003336 - Nozzle Boot (electronic model) (item
)
~ OR ~
M05632B001 - Nozzle Boot (mechanical model) (item
• 003719 - Nozzle Hook Kit (item
)
• 026850 - Nozzle Boot Gasket (item
)
1
Remove the four screws securing the existing nozzle boot and remove the nozzle boot and
existing gasket. Save screws for reassembly.
2
Mount new Nozzle Boot Gasket (item
) and secure with the
screws saved in step
on
).
3
Remove the hardware from the existing nozzle hook. Save all mounting hardware for
reassembly.
4
Remove the two plugs from the lower mounting holes of side panel and place them in the two
upper holes.
5
Install the new Nozzle Hook Kit (item
) in the two lower holes in the side panel and secure
using mounting hardware saved in step
on