Page 6: Caution

Installing the M06184K00X Vapor Recovery Kit
Page 6
MDE-4487C Atlas™ Dispenser Vapor Recovery Kit (M06184K00X) Installation Instructions · September 2008
Installing the M06184K00X Vapor Recovery Kit
Preparing for the Installation
1
Request permission from the Manager/Owner to remove power from the unit and then remove
power using normal procedures. Perform the lockout/tagout safety procedures.
2
Activate the emergency shutoff valve.
3
Ensure that you have the proper kit for the model dispenser to be retrofitted.
4
Be prepared to follow all applicable safety rules and procedures.
Mounting the Emco Splitter to Dispenser
The mounting holes on the dispenser for the Emco Splitter (item
) are already on the unit.
Mount the splitter per the following instructions.
Use a UL-approved joint compound on all pipe threads. DO NOT use Teflon
®
tape.
CAUTION
1
Knock out the plastic plugs for the mounting holes near the bottom of the hose side of the
Atlas unit.
2
Using a length of 3/4 inch pipe (nipple) long enough to position the splitter (item
the flange is flush with the dispenser wall, screw the pipe into the splitter. See
.
Figure 2: Mounting 066817 Splitter to Dispenser
1-7/8” - 12 UN per
SAE J475 &
J513 Coaxial
Connection to
Nozzle
3/4” NPT Fuel Connection
from Dispenser
3/4” NPT
Nipple
(not supplied)
Vapor Pipe to
Underground
Tank
Four 5/16-18 x 1”
Screws and Nuts
Dispenser Wall
066817 Splitter
(
on
3/4” Elbow
(not supplied)
Outside of Dispenser
Inside of Dispenser