beautypg.com

Mounting hose to retriever and splitter, Completing the installation – Gasboy M06184K00X User Manual

Page 10

background image

Completing the Installation

Atlas

is a trademark of Gilbarco Inc. Gasboy

®

is a registered trademark of Gilbarco Inc. Teflon

®

is a registered trademark of E. I. DuPont

de Nemours and Company. UL

®

is a registered trademark of Underwriters’ Laboratories, Inc.

© 2008 GASBOY
7300 West Friendly Avenue · Post Office Box 22087
Greensboro, North Carolina 27420
Phone 1-800-444-5529 ·

http://www.gasboy.com

· Printed in the U.S.A.

MDE-4487C Atlas™ Dispenser Vapor Recovery Kit (M06184K00X) Installation Instructions · September 2008

Mounting Hose to Retriever and Splitter

The following parts are required to mount the Hose to the Retriever and Splitter:

• 038502 - Emco VR Nozzle (item

12

)

• 030301 - GY Hose, 7.5 feet (item

13

)

• 044007 - Breakaway (item

17

)

• 030303 - GY Hose, 4.5 feet (item

18

)

1

Using white lithium-based grease, lubricate both ends of the 7.5-feet GY hose threads (item

13

) and O-Rings.

2

Thread one end of the hose into the Emco Splitter (

Figure 2

on

page 6

and item

14

,

Figure 3

on

page 8

) on the dispenser unit.

3

Thread the breakaway (item

17

) on the other end of the hose.

4

Using white lithium-based grease, lubricate both ends of the 4.5-feet GY hose threads (item

18

) and O-Rings.

5

Thread one end of the hose into the breakaway. Thread the Emco VR Nozzle (item

12

) onto

the other end of the hose.

6

Tighten all connections securely (four connections).

7

Install the clamp on the Clamp and Reel Assembly (item

1

) to the hose. Position the clamp on

the hose such that the hose does not touch the ground when the nozzle is positioned in the
boot.

8

Pull out the hose and check the operation of the Clamp and Reel Assembly retriever and also
check the lay of the hose.

Completing the Installation

1

Inform the Manager/Owner that power will be restored to the unit and then restore power
using normal procedures. Remove the lockout/tagout and return to normal operation.

2

Release the emergency shutoff valve.

3

Test the system for leaks. For detailed information regarding leak tests, refer to MDE-4334
Atlas Start-up/Service Manual.