beautypg.com

Mounting hose to retriever, Completing installation – Gasboy M06430K00X User Manual

Page 12

background image

Hose and Retriever Installation

Page 12

MDE-4522A Atlas™ Self-Contained Pump Vapor Recovery Kit M06430K00X Installation • November 2006

3

Remove the hardware from the existing nozzle hook. Save all mounting hardware for
reassembly.

4

Remove the two plugs from the lower mounting holes of side panel place them in the two
upper holes.

5

Install the new Nozzle Hook Kit (item 20) in the two lower holes in the side panel and secure
using mounting hardware saved in step

3

(

Figure 6

).

Mounting Hose to Retriever

Items needed for this procedure are the following:

• Item 12 – 038502 Emco VR Nozzle
• Item 13 – 030301 GY Hose, 7.5 feet
• Item 17 – 044007 Breakaway
• Item 18 – 030303 GY Hose, 4.5 feet

1

Using white lithium-based grease, lubricate both ends of the 7.5-foot GY hose threads (item
13) and O-rings.

2

Thread one end of the hose into the Emco splitter (item 14,

Figure 6

) on the dispenser unit.

3

Thread the breakaway (item 17) onto the other end of the hose.

4

Using white lithium-based grease, lubricate both ends of the 4.5-foot GY hose threads (item
18) and O-rings.

5

Thread one end of the hose into the breakaway. Thread the Emco nozzle (item 12) onto the
other end of the hose.

6

Tighten all connections securely (four connections).

7

Install the clamp on the clamp and reel assembly (item 1) to the hose. Position the clamp on
the hose such that the hose does not touch the ground when the nozzle is positioned in the
boot.

8

Pull out the hose and check the operation of the clamp and reel assembly retriever and also
check the lay of the hose.

Completing Installation

1

Inform the manager/owner that power will be restored to the unit; then restore power using
normal procedures. Remove the lockout/tagout and return to normal operation.

2

Release the emergency shutoff valve.

3

Test the system for leaks.