MDE-4369 Aviation Tubing Retrofit Kit for Gasboy® Q Models Kits M05023K001 & K05023K002 • October 2004

Page 7

Installing the M05023K001 Kit for Suction Pumps

9

Install new steel tubing and new O-Rings, (Q10068 14 at meter flange and 049002 at the
pumping unit flange) and attach steel tubing using existing bolts. (The use of silicone grease
helps to hold O-rings in place during assembly.)

10

Return power to pump and run fuel through the pump and inspect for leaks.

11

Purge all air from unit (usually 10 gallons is recommended).

12

Remove catch basin, tools and absorbent materials. (Dispose of absorbent materials and fuels
in a safe manner. Do not dispose of them in station trash receptacles or in the pump pit box.)

13