Page 4-6 MDE-5044A Atlas® DEF Operation, Diagnostics, and Recommended Spare Parts Manual · April 2014

Electronic Calibration (E-CAL) Adjustment for E-85/DEF Unit

Diagnostics, Calibration, and Troubleshooting

Electronic Calibration (E-CAL) Adjustment for E-85/DEF
Unit

The E-85/DEF unit must be calibrated electronically. To calibrate the unit, proceed as follows:
Notes: 1) If the unit is two-sided, then the calibration procedure must be performed

individually on each side.

2) The calibration switch is located on the J-box side of all three E-85 unit types

(see

Figure 4-3

).

Figure 4-3: Calibration Switch and J-box

Calibration Switch

(i)

(ii)

1

Slide the back cover and turn the calibration switch to “Calibrate” position (up).

a

Locate the calibration assembly, slide the Weights and Measures (W&M) seal metal cover

toward the exterior of the unit.

b

Locate the inside switch for side B or the outside switch for side A. Place the switch in the

up position to activate the calibration procedure.

Number “7” appears in the Most Significant Digit (MSD), left-most digit of the pump display
and will remain throughout the procedure (see

Figure 4-4

).

Figure 4-4: Turning on Calibration Switch