DEF LED Functions - Cold Weather Units
Page 3-2 MDE-5044A Atlas® DEF Operation, Diagnostics, and Recommended Spare Parts Manual · April 2014
DEF LED Functions - Cold Weather Units
9800 CPU Board
Following table shows the LEDs on the 9800 CPU board:
LED
LED Status
Condition
Pump Handle
On
Nozzle out
Pulsar
On (Flashing) Product flowing
+5 VDC
On
Always
Slow LED
On
Nozzle out and authorized
Fast LED
Sub LED
Coriolis Meter Interface Board
Following table shows the LEDs on the coriolis meter interface board
:
LED
LED Status
Condition
CR 1
On
+24 VDC power supply enabled
CR 2
-
-
CR 3
On
Meter side ‘A’ enabled with the pump handle
CR 4
On
+5 VDC power supply enabled
CR 5
Off
Pump not in frozen state
Temperature Control Board
LED
LED Status
Condition
CR 1
On
Power supplied to the fan
CR 2
On
Power supplied to the heater
Note: Both CR 1 and CR 2 will activate together when the thermostats
detect a temperature of 43 °F (6.1 °C) in the cabinet.
Following table shows the LEDs on the temperature control board:
DEF Warm Weather Units
DEF warm weather units operate and function the same as the DEF cold weather units without
the functions of the heater/fan assembly, thermostats, and temperature control board, as these
items are not included in the DEF warm weather unit.