Atlas 9862 def dispenser status/error codes, Atlas 9862 def dispenser status/error codes -5, Important information – Gasboy DEF Atlas User Manual
Page 17: Customer display

MDE-5044A Atlas® DEF Operation, Diagnostics, and Recommended Spare Parts Manual · April 2014
Page 4-5
Diagnostics, Calibration, and Troubleshooting
Diagnostics Procedure for Cold Weather Problems
Atlas 9862 DEF Dispenser Status/Error Codes
Code
Status
01
Random Access Memory (RAM) failure
02
Read Only Memory (ROM) failure
55
Power failure
56
Pulsar error
57
Timed out
58
Limit cutoff
59
Flow error meter 1
60
Flow error meter 2
99
Product unavailable
554
Power failure (calibration mode)*
564
Pulsar failure (calibration mode)*
574
Timed out (calibration mode)*
584
Limit cutoff (calibration mode)*
993
Invalid calibration factor*
994
Invalid calibration transaction
*During calibration testing.
Customer Display
Code
Definition
7
Calibration switch on
5, 10, 15, 20, 50
Prover can sizes
The DEF nozzle with the blue cover requires a magnetic actuator to dispense the
product. The DEF nozzle with the black cover does not require a magnetic actuator.