Page 25
Completion Checklist
Start-up
5 – Start-up
Completion Checklist
The following information must be reviewed to verify the proper installation of the satellite
dispensing unit. If the installation does not meet the following criteria, correct the problem
before the start-up is performed.
1
If connected to an Atlas Series 9800K dispenser, to avoid damage to the CPU PCB board,
verify if the RESET COMPLETE, FAST FLOW, SUBM. STARTER DRIVE, and SLOW and
FAST SATELLITE RETURN wires are not shorted to conduit or chassis.
2
The unit must be properly secured to the island.
3
All plumbing must be complete and tight. All liquid-carrying lines must be checked for leaks.
4
All conduit work must be complete. All junction box covers must be secured. Conduits must
not be sealed until the wiring is verified through proper operation.
5
The unit must be properly grounded.
6
Before any testing begins, remove any water in the tank through a fill opening, using a suitable
pump. Do not use the Gasboy pump or dispenser and submersible pump to remove water.
Serious damage may occur.
7
A sufficient volume of fuel must be put in the tank to ensure that the liquid level is high
enough to allow the submersible pump to operate efficiently (dispensers). This section
provides information specific to the installation of Atlas pumps/dispensers.
Start-up
After successfully verifying the installation against the completion checklist, the unit is ready
for start-up. To perform start-up of the satellite dispensing unit, proceed as follows:
1
Turn on the circuit breaker(s) for the various control lines to the dispenser to be tested.
2
Remove the nozzle for Side 1 from its holder and turn on the pump handle.
3
Dispense fuel. If the unit contains a slow/fast flow valve, verify if it opens. Check all plumbing
for leaks at this time.
4
Turn the pump handle off. Open the nozzle. No fuel must be dispensed.
5
For twin models, repeat steps
for the other untested dispenser.