Configure mdc1200, Mdc feature order, To enable an mdc type – GAI-Tronics L3149B C200 Advanced Deskset User Manual
Page 67: To disable an mdc type, To change the order of the selected mdc types, Mdc pretime timers, Tx pretime, Tx post pretime, Acknowledge pretime, Mdc id

L3149B (C200) Advanced Tone Remote Desk Set
Programming
61
Configure MDC1200
MDC Feature Order
This feature allows you to select which manual paging types or MDC types will be available on the
C200. You may also determine the order in which the selected paging types appear.
N
OTE
: Paging types enabled have no effect on which MDC types are available in any part of the
programming software. All paging and MDC types will be available.
To Enable an MDC Type
Highlight the paging type's name under Available MDC Types. More than one may be selected. Click
on the Add button. The name(s) moves to the MDC Types in Use area. The new entry(entries) are
placed at the end of the list.
To Disable an MDC Type
Highlight the paging type's name under MDC Types in Use. More than one may be selected. Click on
the Remove button. The name(s) moves to the Available MDC Types area.
To Change the Order of the Selected MDC Types
Highlight only one paging type under MDC Types in Use. Click on Move Up to place it higher on the
list. Click on Move Down to move it lower in the list.
Click on an area of the window for a description of its function.
MDC Pretime Timers
TX Pretime
The TX Pretime is the time the desk set waits after the transmission has begun before transmitting the
data. For tone control, the time begins after the end of the function tone. The valid range for this
parameter is 0–2000 ms in 10 ms increments.
TX Post Pretime
The TX Post Pretime is the time after the
TRANSMIT
button is released, before the desk set transmits a
Post PTT ID if Post PTT ID is enabled in the MDC Flags. The valid range for this parameter is 0 to
2000 ms
in 10 ms increments.
Acknowledge Pretime
The Acknowledge Pretime is the time the desk set waits after the beginning of a transmission to
acknowledge the receipt of a MDC message before data is transmitted. For tone control the time begins
after the end of the function tone. The valid range for this parameter is 0 to 2000 ms in 10 ms
increments.
MDC ID
The MDC ID is the RapidCall ID of the desk set. This ID is unique to all units in the same system. It is
used when addressing other units or determining whether a specific RapidCall message is intended for
itself. The valid range is from 0001 to DEEE. The ID cannot be 0000, cannot contain a wildcard or F,
and must be less than E000.