L3149B (C200) Advanced Tone Remote Desk Set
Installation
31
Line Connections for Local Control (L3147A) Operation
When programmed for local operation (L3147A) the desk set provides extended local control of the
radio. This operation requires PTT and monitor to be connected to J701 of the relay module in the base
of the desk set as noted in the chart below. Additionally, if parallel L3149B Desk Sets (in local control
mode) are to be used, the connection of PTT Sense and Monitor Sense allows proper operation of the
system. If a CDM1550 LS Mobile Radio is used, the clear-to-send of the radio must be connected to the
clear-to-send input that has been configured with the programming software.
The table below shows the connections that must be made between the L3149B relay module and the
radio. The items in bold are pertinent connections. Also note that the radio must provide the appropriate
pull-up (>= 47 kilohms) for proper operation.
J701 Pin Description
Connect To:
1
Programmable Input
CTS input (CDM1550 LS LTR Support)
2 Ground
Return
Radio Ground (same as pin 24)
3
Monitor Sense Input
Pin 13 if parallel units used
4
PTT Sense Input
Pin 16 if parallel units used
5
Programmable Input
CTS input (CDM1550 LS LTR Support)
6
Relay 4-1 N/C Contact
7
Relay 4-1 Common
8
Relay 4-1 N/O Contact
9
Relay 4-2 N/C Contact
10
Relay 4-2 Common
11
Relay 4-2 N/O Contact
12
Relay 3 N/C Contact
13
Monitor Output
Radio Monitor Input
14
Relay 3 N/O Contact
Pin 2 or 24
15
Relay 2 N/C Contact
16
PTT Output
Radio PTT Input
17
Relay 2 N/O Contact
Pin 2 or 24
18
Relay 1-1 N/C Contact
19
Relay 1-1 Common
20
Relay 1-1 N/O Contact
21
Relay 1-2 N/C Contact
22
Relay 1-2 Common
23
Relay 1-2 N/O Contact
24
Ground Return