A tone duration, B tone duration, Talk now timer for plectron – GAI-Tronics L3149B C200 Advanced Deskset User Manual
Page 64
Programming
L3149B (C200) Advanced Tone Remote Desk Set
58
Tone Group P1
643 672 701 732 765 799 834 871 910 950
Tone Group P2
992 1036 1082 1130 1180 1232 1287 1344 1403 1465
Tone Group P3
1530 1598 1669 1743 1820 1901 1985 2073 2164 2260
Tone Group P4
2361 2465 2575 2688 2807 2932 3062 3197 3339 3487
Tone Group P5
282.2 294.7 307.8 321.4 335.6 330.5 366.0 382.3 399.2 416.9
Tone Group P6
435.3 454.6 474.8 495.8 517.8 540.7 564.7 589.7 615.8 742.5
A Tone Duration
This parameter sets the first tone duration of the Plectron sequence. The valid range is 0.5 to 4.5
seconds in 0.5 second increments.
N
OTE
: This parameter affects alias paging as well.
B Tone Duration
This parameter sets the second tone duration of the Plectron sequence. The valid range is 0.5 to 4.5
seconds in 0.5 second increments.
N
OTE
: This parameter affects alias paging as well.
TALK NOW Timer for Plectron
This parameter specifies the length of time a user is allowed to talk after the paging signal. If the
TRANSMIT
button is pressed during the TALK NOW time, the unit continues to transmit until the button
is released. The range is 0 to 45 seconds. If 0 seconds is selected, the operator is not allowed to talk
after the page.