The info menu item – Fronius Energy Package User Manual
Page 48
46
The INFO menu item
Measured values
PV ins.
Insulation resistance of the photovoltaic system and the storage system
Ext. lim.
External power reduction in per cent e.g. specified by grid operator
U PV
Current PV voltage on the terminals even if the inverter is feeding in no power whatsoever
GVDPR
Grid voltage-dependent power reduction
Fan #1
Percentage of target output for fan
PSS status
The status of the most recent inverter fault can be displayed.
IMPORTANT! Due to the low level of insolation early in the morning and in the evening,
the status codes 306 (Power low) and 307 (DC low) are displayed routinely at these times
of day. These status codes do not indicate any kind of fault.
-
Press the 'Enter' key to see the status of the power stage set and the most recent fault
-
Use the 'Up' and 'Down' keys to scroll through the list
-
Press the 'Back' key to close the status and fault list
Grid status
The five most recent grid faults can be displayed:
-
Press the 'Enter' key to see the five most recent grid faults
-
Use the 'Up' and 'Down' keys to scroll through the list
-
Press the 'Back' key to close the grid fault display
Device informa-
tion
For displaying the settings that will be of relevance to a utility company. The values shown
will depend on the country setup or the device-specific settings of the inverter.
Display area
General / Country-specific setting / MPP Tracker / Grid monitor-
ing / Grid voltage limits / Grid frequency limits / Q-mode / AC
power limit
General:
Device type
Fam.
Country-specific set-
ting:
Setup
Specified country setup
Version
Version of country setup
Group
Group for updating the inverter software
MPP Tracker:
PV Tracker