Fronius Energy Package User Manual
Page 43
41
EN
Night mode
DATCOM night mode; controls DATCOM and display operation during the night or when
the DC voltage is insufficient
Contrast
Set the contrast on the display
Since the contrast is temperature-dependent, it may be necessary to adjust the setting un-
der the “Contrast” menu item when the environmental conditions change.
Illumination
Initial setting for display illumination
The “Illumination” menu item only relates to the display backlighting.
Setting range
German, English, French, Dutch, Italian, Spanish, Czech, Slo-
vak, etc.
Setting range
AUTO / ON / OFF
Factory setting
OFF
AUTO:
DATCOM mode is always in effect whenever Fronius system monitoring is
active.
The display remains dark during the night, but can be activated by pressing
any key.
ON:
DATCOM mode is always in effect. The inverter supplies 12 V continuously
to power the Fronius Solar Net. The display is always active.
IMPORTANT! If DATCOM night mode is set to ON or AUTO when there are
Fronius Solar Net components connected, then the inverter's current con-
sumption during the night will increase to around 7 W.
OFF:
IMPORTANT! If a battery has been connected to the system and activated,
Night mode must not be set to OFF.
DATCOM will not run at night, the inverter will not need any AC current in
order to supply power to the internal communication system.
The display is switched off during the night and the Fronius system monitor-
ing datalogger is not available.
Setting range
0 - 10
Factory setting
5
Setting range
AUTO / ON / OFF
Factory setting
AUTO
AUTO:
The display backlighting is activated by pressing any key. If no key is
pressed for 2 minutes, the display backlighting will go off again.
ON:
The display backlighting remains permanently on when the inverter is active.
OFF:
The display backlighting is permanently switched off.