Fronius Energy Package User Manual
Page 125
123
EN
System monitor-
ing
Explanation of
footnotes
1)
The values stated are defaults; the inverter is configured specifically to suit the re-
quirements of the relevant country.
2)
Depending on the country setup or device-specific settings
(ind. = inductive; cap. = capacitive)
3)
PCC = interface to the public grid
4)
Maximum current from the inverter to the solar module when an error occurs in the
inverter
5)
Guaranteed by the electrical configuration of the inverter
6)
Current peak when switching on the inverter
Interfaces
Connection to inverter
Modbus RTU (RS485)
Fronius Solar Battery
Battery 9.0
Battery 10.5
Battery 12.0
Supply voltage
12 V DC
Energy consumption
< 2 W
Dimensions
132 x 103 x 22 mm
5.2 x 4.1 x 0.9 in.
Ethernet (LAN)
RJ45, 100 Mbit
WLAN
IEEE 802.11b/g/n client
Ambient temperature
-20 - +65 °C
-4 - +149 °F
I/O connection specifications
Voltage level of digital inputs
Low = min. 0 V - max. 1.8 V
High = min. 3 V - max. 24 V (+20%)
Input current values of digital inputs
Dependent on input voltage;
input resistance = 46 kohms
Switching capacity of digital outputs when
supplied by Datamanager plug-in card
3.2 W
12.8 V
in total for all 4 digital outputs
Max. switchable inductive loads at digital
outputs
76 mJ
(per output)
Modbus RTU
RS485 2-wire
Factory settings for RS485 interface:
Speed
Data frames
9600 baud
1 start bit
8 Data bits
No parity
1 stop bit