Flowserve 400MD Logix User Manual
Page 63

Function
Block
Parameter
3400 Alert/Alarm
Items GREYED OUT
are factor default
masked off (NOT ACTIVE)
Defined
Bits
XD_MAIN_
BLOCK_ERR
BLINK_
CODE
LED
Blink
MAIN
CONTROLLER_STATE_STATUS
INITIALIZING
FACTORY_RESET_STATE
JOG_COMMAND_MODE
SIGNATURE_IN_PROGRESS
CONTINUOUS_FRICTION_MODE
0X01
0X02
0X10
0X20
0X40
NONE
MAINT_NOW
NONE
NONE
NONE
0
1
4
5
6
YGGR
RGRR
YGYY
YGYY
NONE
MAIN
POSITIONER_STATUS
POSITION_DEVIATION_ALARM
SOFT_STOP_UPPER_LIMIT
SOFT_STOP_LOWER_LIMIT
POSITION_UPPER_LIMIT
POSITION_LOWER_LIMIT
MPC_ACTIVE
LOCAL_INTERFACE_DISABLED
ERROR_HISTOR_RESET
0X01
0X02
0X04
0X08
0X10
0X20
0X40
0X80
MAINT_NOW
NONE
NONE
NONE
NONE
NONE
NONE
NONE
8
9
10
11
12
13
14
15
RRRR
GYGY
GYGY
GYGG
GYGG
GGGY
GGYG
NONE
MD
MECHANICAL_STATUS
ACTUATOR_RATIO_WARNING
PNEUMATIC_INABILITY_TO_FAI_SAFE
FRICTION_HIGH_WARNING
FRICTION_LOW_WARNING
FRICTION_HIGH_ALARM
FRICTION_LOW_WARNING
VALVE_CYCLES_WARNING
VALVE_TRAVEL_WARNING
0X01
0X02
0X04
0X08
0X10
0X20
0X40
0X80
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
16
17
18
19
20
21
22
23
YYYY
YRRR
YRYG
YRGY
RRGR
RRGY
GRGG
GRGG
TECH
ELECTRONIC_STATUS
TEMPERATURE_HIGHT_WARNING
TEMPERATURE_LOW_WARNING
SHUNT_VOLTAGE_REFERENCE_ERROR
PIEZO_VOLTAGE_ERROR
WATCH_DOG_TIME_OUT
NV_RAM_CHECKSUM_ERROR
LOSS_OF_INTER_PCB_COMM
ELECTRONIC_INABILITY_TO_FAIL_SAFE
0X01
0X02
0X04
0X08
0X10
0X20
0X40
0X80
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
32
33
34
35
36
37
38
39
YYGG
YYGG
RRRY
RRYG
RRRY
RRRY
RRRG
YRRY
TECH
PRESSURE_STATUS
SUPPLY_PRESSURE_LOW_ALARM
SUPPLY_PRESSURE_HIGH_WARNING
SUPPLY_PRESSURE_LOW_WARNING
PORT_1_VALUE_OUT_OF_RANGE
PORT_2_VALUE_OUT_OF _RANGE
PORT_1_RANGE_TOO_SMALL
PORT_2_RANGE_TOO_SMALL
PNEUMATIC_LEAK_WARNING
0X01
0X02
0X04
0X08
0X10
0X20
0X40
0X80
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
40
41
42
43
44
45
46
47
RYYG
YYGR
YYYG
YYGY
YYGY
YYGY
YYGY
YRGR
TECH
INTERLOOP_STATUS
SPOOL_STICKING_WARNING
SPOOL_STICKING_ALARN
SPOOL_CYCLES_WARNING
SPOOL_TRAVEL_WARNING
HALL_SENSOR_UPPER_POSITION
HALL_SENSRO_LOWER_POSITION
0X01
0X02
0X04
0X08
0X10
0X20
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
48
49
50
51
52
53
YRGG
RRGG
GRGG
GRGG
RRYR
RRYR
TECH
OUTER_LOOP_STATUS
FEEDBACK_RANGE_TOO_SMALL
POSITION_OUT_OF_RANGE_0
POSITION_OUT_OF_RANGE_100
NO_MOTION_TIME_OUT
NON_SETTLE_TIME_OUT
INNER_LOOP_OFFSET_TIME_OUT
JOG_CALIBRATE_SET_100_POSITION
0X01
0X02
0X04
0X08
0X10
0X20
0X40
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
MAINT_SOON
56
57
58
59
60
61
62
RGGY
RGGY
RGGY
RGYY
RGYG
RGGR
YGYR
TECH
CONFIGURATION_STATUS
PRESSURE_SENSOR_BOARD_PRESENT
PRESSURE_CONTROL_LOCKED
REVERSED_POT_ROTATION
REVERSED_SPRING
INSUFFICIENT_SPRING
NO_SPRING
0X01
0X04
0X08
0X10
0X20
0X40
NONE
NONE
NONE
NONE
NONE
NONE
72
74
75
76
77
78
NONE
NONE
NONE
NONE
NONE
NONE
Logix 3400MD Digital Positioner LGENIM3405-02 11/13
63