beautypg.com

DR Power 16.50 Pro User Manual

Page 40

background image

36

16.50 PRO DR

®

RAPID-FEED™ CHIPPER

4. Closely inspect the Chipper Knife and Wear Plate for

nicks or dull (rounded) edges (Figure 35).

5. If necessary, repair or replace the Chipper Knife and/or

Wear Plate per the following procedures. If the Knife
and Wear plate do not need maintenance or
adjustment, replace the Hopper.

Removing and Replacing the Chipper Knife

Tools Needed:

• 5/16" Wrench

• 9/16" Socket

• 7/32" Allen wrench

• Awl or Sharp Tool

• Gloves

1. Remove the Belt Guard (see “Removing and Replacing

the Drive Belt” in this Chapter to remove the Belt
Guard).

2. Using a 5/16” Wrench, remove the Self -Tapping

Screws and remove both Knife Access Covers from the
front and back of the Chipper Assembly (Figure 36).

3. Rotate the Flywheel using a stick until the three

countersunk Allen Screws and Lock Nuts attaching the
Knife to the Flywheel are visible through the Access
Openings.

4. Clean out the heads of the Allen Screws with an Awl or

Sharp Tool.

5. Insert a 7/32” Allen Wrench into the head of a screw

(Figure 37).

6. While holding the Allen Wrench, remove the Lock Nut

using a 9/16" socket.

7. Repeat Steps 5 and 6 for the remaining two Allen

Screws.

Chipper Knife
(sharp edge
facing up and
towards you)

Figure 37

Countersunk
Allen Screws and
Locknuts

Flywheel
Slot

Rear Knife Access
Cover (one on the
front side also)

Figure 36

Self -
Tapping
Screws

Chipper
Knife

Figure 35

Wear
Plate

BE CAREFUL AND WEAR GLOVES WHEN WORKING NEAR
THE CHIPPER KNIFE. THE KNIFE EDGE CAN CUT YOU IF
YOU COME IN CONTACT WITH IT.

This manual is related to the following products: