quote. Comments are allowed in upper and lower case and may be changed with the
port in service. Once entered, the comments are displayed on the port verify.


6.2.2 REMOVE

PORT

Syntax: remove port < portnum > < all > < range >

This command is only visible when the unit is logged in. The command takes a user port
out of service, and must be performed before any port-level configuration changes can
occur. The parameter may be a number in the range 1 through the number
of ports on the xxxx. The parameter removes all the serial ports. The
parameter removes a sequential range of ports.

6.2.3 RESTORE

PORT

Syntax: restore port < portnum > < all > < range >

This command, only visible when the unit is logged in, returns a user port to service.
The parameter may be a number in the range of 1 through the number of
serial ports on the xxxx. The parameter restores all the ports. The
parameter restores a sequential range of ports.

6.2.4 DISPLAY

PORT

MEASUREMENTS

Syntax: dmeas port < portnum | all | range >

The dmeas (dm) port command is only visible when the unit is logged in. It displays the
current port-level measurements for the RS-232C port specified by , in a
formatted report on the console. The parameter may be a number in the
range 1 through the number of ports on the xxxx. The parameter will display the
measurements on all ports. The parameter is in the form of “start-end”, and will
display the measurements of the ports in that sequential range inclusive.

6.2.5 VERIFY

PORT

Syntax: vfy port < portnum | all |range >

This command is only visible when the unit is logged in. It displays the configuration of
the port number specified. The parameter may be a number in the range 1
through the number of ports on the xxxx. The parameter will verify all ports. The
parameter will verify a sequential range of ports.

6.2.6

DISPLAY PORT STATUS

Syntax: dstat port < < portnum > | < all > | < range > >

This command is only visible when the unit is logged in. It displays the status of the port
number specified. The parameter may be a number in the range 1 through