the 4000XA and 4180 faceplate. The AC power cube plugs into the circular connector 
labeled 48VDC on the 4284, and the 9480. 
 
Power Over Ethernet 
The 4280, 4284, and 9480 will accept power on the LAN connection using the POE 
specification. When used, no additional power is required by the device. 
 
Redundant Power 
The 4280, 4284, and 9480 may be connected to power on each of their supported 
interfaces. For example, the “Power over Ethernet” may be used at the same time as 
48V power on the circular connector. The power supplies are isolated from each other 
and completely redundant. If one should fail, the other is used without interruption. Note 
that the 4280 may be triple redundant with Power over Ethernet, 48V on its 3-prong 
interface, and 18-72v on its circular connector. 
 
3.2
ALARM RELAY UNIT INTERFACE
The Alarm Relay Unit connector is a three position (Failed Open, Closed, Failed Closed) 
terminal block labeled ALARM on the 4000XA, 4180 or 4280 faceplate. The terminal 
block connectors accommodate 10-awg to 14-awg wire. 
 
3.3 CONSOLE
INTERFACE
The console interface is used for initial configuration, and for StarKeeper® II NMS 
monitoring on an on-going basis.
2
This interface requires a standard RJ45-terminated twisted-pair data cable on the 
4000XA, 4180, 4280, and 4284. It connects as a data terminating equipment (DTE) to 
an asynchronous device and uses RS-232C signaling. It is configured as 9600 bps, 8 
bits, no parity and one stop bit. 
On the 9480, the serial console interface is available on the secondary port pins of the 
DB25 connector (Pins 14 & 16). Once initially configured, all operations may use the 
telnet console. 
 
3.4 4180
RS-232/V.11/RS-530SERIAL INTERFACE
 
The DB25 RS-530 male connector on the 4000XA and 4180 provides support for 
software-selectable device interfaces (V.35 and RS232-C) at data rates up to 2Mbps. 
The DB25 RS-530 interface is a DTE only. The male connector electrically presents a 
data terminal equipment (DTE) interface and supports RS-232C directly. For V.35, a 
standard RS-530 DB25 Female to V.35 Winchester-34 Male adapter is available. 
 
 
2
The xxxx also provides access to the console function through a TCP telnet
connection via a reserved telnet server port (TCP port 1023). This service is available 
only when the unit is in service, and may be protected by Closed User Group 
membership. 
 