Datatek DT-4180 User Manual
Page 61
![background image](https://www.manualsdir.com/files/780742/content/doc061.png)
9 4 8 0 , 4 1 8 0 , 4 2 8 0 , 4 2 8 4 4 0 0 0 X A U s e r
M a n u a l
04/09/09
61
feed) insertion. A value of RMT will insert an LF following a CR whenever it is sent
towards the remote IP endpoint. A value of VC will insert an LF following a CR whenever
it is sent towards the X.25 virtual circuit. A value of BOTH will insert an LF following a
CR in either direction.
The
padcmap=< ON | OFF >
option provides the automatic case mapping from lower
case to upper case. When the option is set to ON, all lower case characters are
automatically converted to upper case. When OFF, no transformations are performed.
The
padapi=< TELNET | RAW >
option provides a means of selecting the PAD virtual
circuit to use raw protocol. The raw protocol is essentially asynchronous, but without
the benefit of Telnet RFC encapsulation. It is used for applications that do not implement
the Telnet RFC. The default for this option is to use the Telnet encapsulation.
The
padcug=[+|-]
parameter allows the virtual circuit connection to be
protected by closed user group membership. The closed user group feature is significant
only for PAD service. The closed user group address entries are defined with the cug
command. Any or all closed user group entries may be assigned with a virtual circuit.
The
calling=
parameter is used to specify the “calling address” on an SVC
call setup packet. Most devices do not require a calling address. This option allows the
specification for a device which does require same.
The
called=
parameter is used to specify the “called address” on an SVC
call setup packet. Most devices do not require a called address. This option allows the
specification for a device that does require same.
The
ext_calling=
parameter is used to specify the “extension calling
address” on the SVC call setup packet of an OSI X.25 connection. The option may be
deleted with the value ‘delete’. This parameter is only required with the OSI X.25
interface.
The
ext_called=
parameter is used to specify the “extension called
address” on the SVC call setup packet of an OSI X.25 connection. The option may be
deleted with the value ‘delete’. This parameter is only required wit the OSI X.25
interface.
The
ulen=< UDATA Length >
parameter specifies the length of the user data field to be
used in an SVC call setup packet. The default is one byte of value 0xC1.
The
udata#=< Hex Byte >
parameter allows modification of the user data field to be
used in an SVC call setup packet. The # may be a number in the range of one through
sixteen. The < Hex Byte > is of the form 0xXX.
The
vccom=”User Comment”
parameter allows the specification of a comment line for
the one or more VCs. The comment may be up to 32 characters in length, and may
contain spaces and some special characters. It may not contain an embedded double