The power source is the biggest difference between domestic and international applications.
International displays run on 240 VAC.
Terminating single-phase power to the internal power termination panel:
Daktronics’ displays used in international applications are equipped with different power
termination panels than domestic displays. However, the termination method is similar to domestic
termination discussed in Section 3.5.
1. Open the display as explained in
Section 6.2 and locate the power
termination panel.
2. Route the cable through conduit to the
back of the display. Remove the rubber
plug from the ¾” knockouts for access,
being careful not to damage internal
components.
3. Remove the cover of the power
termination panel.
4. Connect the neutral wire to the neutral
lug and the live wire to the Line 1 lug,
as shown in Figure 33.
5. The ground wire connects to the
grounding bus bar.
Figure 33: 240 V Single-Phase Power Termination